Shielded vs Unshielded: Choosing Cables for Telecom Devices

Shielded vs Unshielded: Choosing Cables for Telecom Devices

In telecommunications infrastructure, the choice between shielded (STP) and unshielded (UTP) cables is pivotal for balancing electromagnetic interference (EMI) resistance, cost efficiency, and deployment flexibility. This article dissects structural distinctions, performance benchmarks, and scenario-based guidelines to empower informed decisions in modern network design.

Ⅰ. Structural Differences

ComponentSTP Shielded Twisted PairUTP Unshielded Twisted Pair
Shielding LayerIncludes a metal foil (such as aluminum foil) or braided mesh shielding layer, which wraps around the wire pairs or the entire cable to suppress external electromagnetic interference (EMI) and radio frequency interference (RFI).No additional shielding layer; relies solely on the twisted structure of the wire pairs to reduce internal crosstalk.
InsulationEach twisted pair is individually wrapped with an insulating layer, and some models add an outer sheath for the overall shielding layer.Only plastic insulation layers (such as polyethylene, PE) are used between the twisted pairs, with no overall shielding.
ConductorTypically uses thinner copper conductors (such as 24 AWG) to accommodate the multi-layer shielding structure.Thicker conductors (such as 23 AWG) with no shielding layer restrictions, resulting in a larger wire diameter.
JacketThe outer sheath is thicker, and some models add tensile fibers or flame-retardant materials (such as LSZH).The sheath is thinner and more flexible, making it easier to bend and install.
GroundingRequires grounding through a dedicated grounding wire or connector (such as a metal RJ45); otherwise, the shielding will fail.No grounding required, making installation simpler.
STP SubtypeStructureApplication Scenario
FTP (Foiled Twisted Pair)Single-layer aluminum foil wraps all wire pairs, with lower cost.Medium interference environments (such as office buildings near elevator areas).
S/FTP (Shielded/Foiled TP)Each wire pair is individually shielded with aluminum foil + overall braided mesh shielding, providing the strongest interference resistance.Extreme interference environments (such as factories, substations).
U/FTP (Unshielded/Foiled TP)Only each wire pair is individually shielded with aluminum foil, with no overall shielding layer.Local high-frequency interference (such as around medical equipment).
AspectSTP AdvantageUTP Advantage
Interference ResistanceThe shielding layer can reduce external interference by over 90% (test value).Relies on the twisted structure to reduce internal crosstalk, with weak external interference suppression.
Weight and FlexibilityWeight increases by 20%-30%, with a larger bend radius (follow the 10:1 rule).Lightweight design, with a smaller bend radius (4:1), suitable for confined spaces.
Signal AttenuationThe shielding layer may introduce additional capacitance, resulting in slightly higher attenuation of high-frequency signals (>500MHz).No shielding layer capacitance effect, with more stable short-distance high-frequency signals.
Standard ComplianceMust comply with strict grounding standards such as IEC 61156-5/6.Complies with the universal TIA/EIA-568 standard, with strong compatibility.
  1. STP:
    • Outer jacket → Overall shielding layer (aluminum foil/braided mesh) → Twisted pairs (individually insulated) → Copper conductors
  2. UTP:
    • Outer jacket → Twisted pairs (only plastic insulation) → Copper conductors

Ⅱ. Performance Comparison

Interference TypeSTP PerformanceUTP PerformanceTesting Standard
Electromagnetic Interference (EMI)
(e.g., motors, transformers)
The shielding layer can attenuate interference by 60-90 dB (at 100 MHz)Relies solely on the twisted structure, attenuation <30 dBIEC 61000-4-6
Radio Frequency Interference (RFI)
(e.g., 5G base stations, WiFi)
Aluminum foil shielding can reflect 90% of high-frequency signalsHigh-frequency signals easily couple to the cable, requiring additional filteringANSI/TIA-1152
CrosstalkEach pair is individually shielded, near-end crosstalk (NEXT) < -70 dBHigher crosstalk between adjacent pairs (NEXT ≈ -50 dB)TIA-568.2-D
ParameterSTPUTPApplication Scenario
Maximum Bandwidth
(e.g., CAT6A)
500 MHz (shielding optimizes high-frequency stability)500 MHz (unshielded performs better over short distances)Data center backbone
Signal Attenuation
(100 meters @ 100 MHz)
20.1 dB (slightly increased loss due to shielding layer capacitance)19.8 dB (slightly lower loss without shielding layer)Long-distance transmission
Bit Error Rate (BER)≤10⁻¹² (remains stable under strong interference)≤10⁻¹⁰ (significantly worse in high-interference environments)Industrial control systems
ScenarioSTP SolutionUTP Solution
High-Security Networks
(government, finance)
The shielding layer prevents electromagnetic leakage (TEMPEST protection), complying with NIST SP 800-88 standardsRelies on AES-256 encryption technology, with weak physical layer protection
High-Temperature/Humid EnvironmentsThe metal shielding layer blocks moisture, and flame-retardant jackets (such as LSZH) can withstand temperatures up to 75°COrdinary PVC jackets age easily (only withstand temperatures up to 60°C)
Vibration Environments
(vehicle-mounted, factories)
Braided mesh shielding layer resists mechanical stress, providing more reliable connectionsLong-term vibration can easily cause RJ45 connectors to loosen
Cost DimensionSTPUTP
Initial Purchase Cost
(CAT6A/meter)
$2.5-$4.0 (including shielding materials and grounding components)$1.2-$2.0 (only basic materials)
Installation and Maintenance CostsRequires specialized grounding tools and labor (+30% labor cost)Plug-and-play, saving 50% deployment time
Lifecycle CostOver 10 years (interference resistance extends equipment life)6-8 years (interference may accelerate equipment failure)
CategorySTPUTPNotes
Anti-Interference53STP wins in EMI/RFI scenarios
Transmission Distance4————

Ⅲ. Application Scenarios

ScenarioRecommended CableKey RequirementsTechnical Support
Industrial Automation
(e.g., robot control, PLC systems)
STP (S/FTP type)Withstand high-frequency electromagnetic interference (EMI ≥ 60 dB) from motors and invertersIEC 61000-6-2 Industrial Interference Standard
Data Center BackboneSTP (Cat6A and above)10Gbps long-distance transmission (>55 meters), reduce bit error rate (BER < 10⁻¹²)TIA-942 Data Center Standard
Outdoor Telecom CabinetsSTP (with metal braided mesh shielding)Lightning protection (voltage ≥ 6kV), moisture resistanceGR-487 Outdoor Equipment Environmental Standard
Hospital MRI RoomsSTP (double shielding + drain wire)Isolate strong magnetic field interference (≥1.5T), avoid data packet lossISO 13485 Medical Device Compatibility
Smart Home IoTUTP (Cat6)Short distance (<30 meters), cost-effective, supports PoE power supplyTIA-568.2-D Residential Wiring Standard
Military CommunicationsSTP (full shielding + armored jacket)Protect against electromagnetic pulses (EMP), resist physical damageMIL-STD-461G Military Electromagnetic Standard
Scenario ParametersSTP Application SolutionUTP Application Solution
Factory Production Line (dense interference sources)Signal stability: 99.99%
Mean time between failures: >5 years
Maintenance cost: $200/year/node
Signal stability: 95%
Mean time between failures: 2-3 years
Maintenance cost: $500/year/node
Office Local Area Network (low interference)Over-designed, 40% cost increase
Poor grounding may cause failures
Optimal cost-effectiveness
Deployment speed increased by 50%
Traffic Signal Control SystemResistant to vehicle radio interference (5G/LTE)
Supports wide temperature range (-40°C~85°C)
Requires additional signal filters
Limited temperature adaptability (0°C~60°C)
Hybrid CaseSTP Usage RatioUTP Usage RatioAdvantages
Smart Factory Network70% (backbone/control layer)30% (sensor access layer)Interference resistance in backbone, cost reduction at endpoints
5G Base Station Backhaul Network100% (fiber + STP hybrid cable)0%Fiber for primary transmission, STP backup link for lightning protection
Airport Terminal Network50% (security check/scheduling area)50% (waiting area WiFi)Shielding in high-security zones, economical deployment in public areas
  1. Is there any of the following interference?
    • Yes → Choose STP: Industrial equipment/Medical instruments/Military EMP
    • No → Proceed to Step 2
  2. Is the transmission distance >55 meters?
    • Yes → Choose STP (Cat6A and above)
    • No → Proceed to Step 3
  3. Is PoE power supply required?
    • Yes → Choose UTP (Cat5e and above)
    • No → Choose UTP (Basic Cat6)

Ⅳ. Selection Guidelines

FactorSTP Preferred ScenariosUTP Preferred ScenariosVerification Method
EMI/RFI Interference IntensityFactory workshops (>30 V/m), medical equipment areas (near MRI), around 5G base stationsOffices (<3 V/m), homes, environments without large motorsElectromagnetic field strength meter testing
Transmission Distance>55 meters (Cat6A and above require shielding to ensure 10Gbps stability)<30 meters (PoE power supply or Gigabit network)Network planning software simulation
Security LevelGovernment/military facilities (TEMPEST protection), financial data centers (PCI-DSS compliance)Ordinary commercial networks (HTTPS encryption is sufficient)Security audit standard comparison
Budget LimitationAllow a 40%-60% increase in unit price (including grounding system)Require a cost per port of <$50 (for small and medium-sized projects)Cost-benefit analysis (CBA)
Temperature/HumidityHigh temperature (>60°C), high humidity (>85% RH), outdoor lightning protectionControlled environment (20°C~40°C, humidity 30%~70%)Environmental sensor monitoring
Interference TypeDetection ToolThreshold Reference
Electromagnetic InterferenceSpectrum analyzer (e.g., Rigol DSA815)STP requirement: >30 dBμV/m @100MHz (EN 55032 Class B)
Radio Frequency InterferenceField strength meter (e.g., Narda SRM-3006)STP requirement: >10 V/m @2.4GHz (FCC Part 15)
Electrostatic DischargeESD simulator (IEC 61000-4-2)STP requirement: Contact discharge ≥8kV, air discharge ≥15kV
RequirementSTP SolutionUTP SolutionFormula Reference
10Gbps TransmissionCat6A STP (100 meters)Cat6A UTP (≤55 meters)Bandwidth=0.8×(frequency/√N) (N is the number of pairs)
PoE++ Power Supply (90W)23 AWG STP (ΔT≤5°C) 22 AWG UTP (ΔT≤3°C)Temperature rise formula: ΔT=(I²×R×L)/(k×A)
Cost ItemSTP (USD/node)UTP (USD/node)
Cable (Cat6A)$4.50/meter$2.20/meter
Grounding System$120 (including grounding bus/connector)$0
Installation Labor$25/hour (+30% labor)$25/hour
Maintenance Cycle10 years (MTBF≥100,000 hours)7 years (MTBF≈60,000 hours)
Mistake TypeConsequenceFix
STP Not GroundedShielding layer acts as an antenna, interference +300%Use a 360-degree full-contact shielding RJ45 (e.g., TE Connectivity AMP-TWIST) and connect to the data center grounding network (<1Ω)
UTP Used OutdoorsAccelerated jacket aging (lifespan ↓50%)Replace with LSZH jacketed UTP or a hybrid STP/fiber solution
Mixing Cables with Different Shielding LevelsImpedance mismatch (return loss >28dB)Standardize on FTP or S/FTP types and verify channel performance with Fluke DSX-8000
Ignoring Bend RadiusIncreased high-frequency attenuation (>3dB/bend)STP: Bend radius ≥10×outer diameter;UTP:≥4×外径 U
StandardSTP RequirementsUTP RequirementsTesting Method
TIA-568.2-DShielding layer continuity (<0.1Ω impedance), grounding resistance <5ΩNear-end crosstalk (NEXT) >44dB @250MHzChannel certification testing
ISO/IEC 11801Shielding effectiveness ≥70dB @1GHz (S/FTP type)Insertion loss <21.7dB @100MHz (Cat6)Component-level testing
EN 50173-1Tensile strength ≥50N (armored STP)Bending cycles ≥5000 (UTP flexibility)Mechanical durability testing
  • EMI/RFI exceeds safety thresholds (e.g., >30dBμV/m)
  • Transmission distance >55 meters and rate ≥10Gbps
  • Need to comply with TEMPEST/EMP protection standards
  • Cost-sensitive projects (budget per node <$100)
  • Short distance (<30 meters) PoE power supply (e.g., IP cameras, wireless APs)
  • Low-interference office environment (electromagnetic field strength <3V/m)
  • Backbone Links:Cat6A STP (supports high bandwidth and long distance)
  • Access Layer:Cat6 UTP (reduces cost and simplifies maintenance)
  • Critical Nodes:STP + fiber redundancy (e.g., 5G base station backhaul)

Ⅴ. Technical Standards

StandardApplicable CablesKey RequirementsTypical Scenarios
ISO/IEC 11801-3:2017STP(S/FTP, F/UTP)Shielding effectiveness ≥70 dB @1 GHz, grounding resistance ≤1 Ω (Class EA)Industrial IoT, data center backbone
TIA-568.2-DUTP/STP(Cat5e~8)UTP crosstalk margin ≥3 dB (100MHz), STP shielding continuity (impedance variation <5% over length)Commercial buildings, smart homes
EN 50173-1:2018STPTensile strength ≥50 N (armored), bend radius ≥8×outer diameter (shielded cable)Rail transit, outdoor telecom cabinets
IEC 61156-5:2020STPTemperature range -40°C~85°C, oil/chemical resistance (jacket material certified by UL 1685)Automotive manufacturing, chemical plants
MIL-STD-461GMilitary shielded cablesEMP protection (100 kV/m transient), tensile strength ≥200 NMilitary communications, aerospace equipment
PerformanceISO/IEC 11801(STP-dominated)TIA-568.2-D(UTP-dominated)Test Method
Shielding≥70 dB @1 GHz (S/FTP type)No mandatory requirement (UTP relies on twisted structure)IEC 62153-4-9(Three-coaxial method)
Insertion LossCat7A: ≤19.8 dB @1000 MHzCat6A: ≤21.3 dB @500 MHzNetwork analyzer(Keysight PNA Network analyzer (e.g., Keysight PNA))
EMI ImmunityMeets IEC 61000-4-6 Level 4 (10 V/m)Meets Level 3 (3 V/m)Radiated immunity test in anechoic chamber
FlexibilityBending cycles ≥5000 (23 AWG STP)Bending cycles ≥10000 (24 AWG UTP) ISO/IEC 14763-2 cyclic test
ScenarioMandatory StandardsRecommended CableCertification
Financial Data CenterTIA-942 (Level 4) + ISO 27001Cat8 STP(Full shielding + grounding bus)DSX-8000 channel certification
Smart Factory (Industry 4.0)IEC 61156-5 + IEC 61000-6-2S/FTP Cat7(Double-layer shielding armor)OM4 fiber redundancy test
5G Base Station Backhaul Network3GPP TS 38.104 + GR-487Hybrid cable (STP + fiber for lightning protection))Lightning impulse test (8/20μs waveform))
Medical Imaging TransmissionISO 13485 + IEC 60601-1-2FTP Cat6A(Single-pair shielding + low-smoke zero-halogen)Biocompatibility test (USP Class VI))
Home Gigabit BroadbandTIA-568.2-D(Residential)Cat6 UTP(Low-cost high compatibility)Simple wire sequence tester
Compliance LevelSTP Incremental CostUTP Incremental CostCost-effectiveness Balance Advice
Basic Level
(TIA-568.2-D)
+40%(Grounding system and shielding connectors)0%(Default compliance)Civil scenarios choose UTP
Industrial Level
(IEC 61156-5)
+80%(Corrosion-resistant jacket + armor)UTP cannot meet standardsHarsh environments mandate STP
Military Level
(MIL-STD-461G)
+200%(EMP protection + hermetic connectors)Not applicableCustomization for special needs
  • STP must meet stringent standards such as ISO/IEC 11801 and IEC 61156, and is suitable for industrial, medical, and military scenarios.
  • UTP follows the TIA-568 series of standards and dominates the civilian and commercial markets.
  • STP: Shielding continuity (<0.1 Ω), grounding effectiveness (<5 Ω grounding resistance).
  • UTP: Near-end crosstalk (NEXT), return loss.
  • Cat8 STP:supports 40Gbps short-distance transmission (30 meters) and complies with the IEEE 802.3bq standard.
  • Green Standards:The EU’s RoHS 3 and REACH regulations restrict halogen materials and promote the use of LSZH jackets.

Leave a Comment

メールアドレスが公開されることはありません。 が付いている欄は必須項目です

表示できるコメントはありません。

ja

Ask For A Quick Quote

Contact Kabolux(sales@kabolux.com) to get a free quote and expert advice on custom cable assembly. Our team will provide the right solution for your project.

Please enable JavaScript in your browser to complete this form.
Enter your full name here
Example: user@website.com
Feel free to ask a question or simply leave a comment